|
|
|
|
|
|
|
Course Criteria
Add courses to your favorites to save, share, and find your best transfer school.
-
3.00 Credits
This course is designed to provide the groundwork for students to be able to design their own total fitness program. This course provides information that is relevant to each person's particular fitness goals, showing students how to alter their programs as their fitness needs change. Individual physical limitations, weight problems and cardio-vascular fitness levels are all significant parts of this course design. (2 C: 1 lect/pres, 1 lab, 0 other)
-
3.00 Credits
This physical education course is an activity class, which emphasizes strength training development and also includes cardiovascular development through continuous aerobic activity for overall fitness. (1 C: 0 lect/pres, 0.5 lab, 0.5 other)
-
3.00 Credits
Reverse Osmosis (OR) Chemistry applies chemical concepts to water and membrane technologies. It relates atomic theory to water contaminants so as to develop a thorough understanding as to why particular contaminants behave the way they do. It includes the means by which those contaminants are measured or characterized. It then applies these principles to reverse osmosis membrane technology in order to recognize how the water characteristics affect the performance of the membrane. (2 C: 0 lect/pres, 0 lab, 2 other)
-
3.00 Credits
Reverse Osmosis (RO) principles develops an understanding of the components and issues involved in an operational RO system. It covers the issues involved in the mechanical configuration of an RO membrane system. It applies design variables, discusses monitoring variables, and demonstrates how to adjust variables in a working RO system. It also illustrates some of the important RO maintenance functions, as well as some critical RO performance concerns. (2 C: 2 lect/pres, 0 lab, 0 other)
-
3.00 Credits
Reverse Osmosis (RO) Monitoring provides the tools necessary for the detailed tracking of the performance of a reverse osmosis (RO) system. It includes common methods of analysis for key water contaminants. It develops an understanding of the RO operating and performance variables, including how they are calculated and applied. It completes with methods that can be used to break down and characterize RO system performance as a means of monitoring or of analyzing system problems. (2 C: 2 lect/pres, 0 lab, 0 other)
-
3.00 Credits
Reverse Osmosis (RO) Cleaning develops an understanding of the chemical nature of cleaning solutions so as to correctly apply them in maximizing RO membrane cleaning effectiveness. It explains how the different cleaning agents work in the removal of common membrane foulants and scale. It then offers methods for correctly cleaning an RO membrane system and evaluating the effectiveness of a cleaning. (2 C: 2 lect/pres, 0 lab, 0 other)
-
3.00 Credits
Reverse Osmosis (RO) Pretreatment details the equipment requirements upstream of a reverse osmosis (RO) system so as to minimize the RO maintenance requirements and increase the longevity of the membrane elements. It begins with the treatment provided by many municipal water treatment facilities and expands this into the requirements more specific for RO systems. This covers media filtration for removal of suspended solids, acid and scale inhibitor injection, or softening, for control of scale formation, and the removal of biocides that might be incompatible with the RO membrane. (2 C: 2 lect/pres, 0 lab, 0 other)
-
3.00 Credits
Reverse Osmosis (RO) Biological Control investigates the nature of biological activity so as to better understand how it can be effectively controlled in a reverse osmosis (RO) system. It discusses the needs that bacteria have for their survival and how their reproduction can foul an RO system. It covers the different methods available for killing and controlling bacteria and how these methods can be applied to an RO system. (2 C: 2 lect/pres, 0 lab, 0 other)
-
3.00 Credits
Reverse Osmosis (RO) System Design applies water quality information to the design of a reverse osmosis (RO) system that is based on meeting the requirements of the membrane element manufacturers. It covers the options available when designing a new system, including design methods for reducing the fouling or scale formation potential of the system. It also includes methods for designing a two-pass RO system, for projecting RO permeate quality, and for estimating the RO system operating and capital equipment costs. (2 C: 2 lect/pres, 0 lab, 0 other)
-
3.00 Credits
Reverse Osmosis (RO) System Analysis provides methods for logically determining the likely cause of a problem in reverse osmosis (RO) performance. It includes methods for isolating the location of the problem within the RO system as a means of gaining insight into the problem. It includes common system performance problems as they relate to the location of the problem. It also covers methods for verifying the suspected problem. (2 C: 2 lect/pres, 0 lab, 0 other)
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Privacy Statement
|
Terms of Use
|
Institutional Membership Information
|
About AcademyOne
Copyright 2006 - 2024 AcademyOne, Inc.
|
|
|